Skip to main content Skip to first level navigation

RICOH imagine. change.


Skip to main content First level navigation Menu
Main content

R5435 Series
2-Cell to 3-Cell Li-ion Battery Second Protection IC

Product Specifications

R5435 Series are CMOS-based high voltage tolerant over-charge protection ICs for Li-ion/Li-polymer secondary battery. The R5435 can detect overcharge of 2-cell to 3-cell Li-ion/ Li-polymer batteries. The R5435 is consists of 3 voltage detectors, a voltage reference unit, an oscillator, a counter, a delay circuit, a logic circuit.
When the over-charge is detected, after the IC internally fixed delay time, the output of COUT becomes "H".
After detecting over-charge, when the cell voltage becomes lower than the over-charge released voltage, the over-charge state is released.
If all the cells voltages become equal or less than the shutdown detector threshold, all the circuits are halted and shut down, as a result, the consumption current of IC itself (Shutdown current) is extremely reduced.
By connect short 2 cells other than monitored cell, over-charge and released delay time can be shortened.
The output type is CMOS.


Manufactured with High Voltage Tolerant Process
  Absolute Maximum Rating 30 V
Low supply current
  Cell voltage 3.9 V, for 3-cell Typ. 3.0 µA
High accuracy detector threshold
  Over-charge detector ±20 mV (Ta=25°C)
±25 mV (Ta=0 to 60°C)
Variety of detector threshold
  Over-charge detector threshold 4.1 V - 4.55 V step of 0.005 V (VDET1n) (n=1, 2, 3)
Over-charge released voltage VDET1n-0 V to VDET1n-0.4 V step of 0.05 V (VREL1n) (n=1, 2, 3)
MIN. 3.95 V
Setting of Output delay time Over-charge detector Output Delay options 2, 4, 6 s (Built-in delay)
Shutdown Function When all the cell voltages become equal or less than shutdown detector threshold, the IC will be into shutdown mode and the consumption current of IC itself becomes extremely small. Even if one of the cells becomes equal or more than shutdown released voltage, the shutdown mode is released.
Shutdown detector threshold Typ. 3.5 V±0.4 V
Shutdown Release Hysteresis none
Shutdown current Max. 0.1 µA
2/3 cell protection enabler By external wiring, 2 or 3-cell protection can be selected.
Over-charge released condition Released by voltage type
COUT output COUT: 4.7 V regulator power supply CMOS output. Active "H"
Delay Time Shortening Function As a result of specified setting, the delay times are shortened, over-charge detector time is shortened from 2 sec to 1/50, 4sec and 6sec to 1/80.
ex. VC2=VC3=VSS, the delay time for cell 1 is shortened. VC1=VC2, VC3=VSS, the delay time for cell 2 is shortened.
VC1=VC2=VC3, the delay time for cell 3 is shortened.
Small package TSOT-23-6, DFN(PLP)1616-6B

Tap to see the table

R5435 Series for Consumer


  • Power source for portable communication equipment
  • Power source for electrical appliances such as PC



Technical Support

Package*1 Reliability*2
DFN(PLP)1616-6B R5435K
TSOT-23-6 R5435N

*1: The package file includes package dimensions, taping specifications, taping reels dimensions, power dissipations, and land pattern (foot pattern).
*2: Reliability file includes a reliability test report and a reflow profile.

Inquiry about products

Technical Support

Inquiries (SSL Form)

Inquiry about business

Purchase, Request for Samples and Documents


Sample Online

Online Distributors